Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum trash enclosure distance from residential units100 ft
the enclosure must be located within 100 feet of the residential units.
- Minimum trash enclosure heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.6 ft
screened with a solid enclosure at least six feet high and include a roof structure.
- Minimum trash enclosure pad thickness4 in
Pads must be a minimum of four-inch-thick concrete.
- Minimum trash enclosures per 20 units1 enclosure
there must be at least one trash enclosure per 20 units
- Trash enclosure bumper size2 in
Bumpers must be two inches by six inches thick
- Trash enclosure pavement live load100 psf
The minimum pavement engineering standard shall be 100 pounds per square foot "live load"
- Dwelling unitsDwelling unitOne independent home: its own kitchen, bathroom and entrance. requiring trash enclosure3 units
Solid waste and recycling-container enclosures are required for new dwelling groups of three or more dwelling units
From the ordinance
Solid waste and recycling-container enclosures are required for new dwelling groups of three or more dwelling units and for all new non-residential development ... For multi-unit residential projects, there must be at least one trash enclosure per 20 units, and the enclosure must be located within 100 feet of the residential units. ... screened with a solid enclosure at least six feet high and include a roof structure.