Dimensional standards
Servicing
- Applies near
- special flood hazard areas
- Geographic extent
- Special flood hazard areas as identified by FEMA FIRMs and FBFMs, including Zones A1-A30 and unnumbered A zones.
Extracted standards
12 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Floodplain
- Maximum increase in water surface elevation1 ft
No development, including landfill, may be permitted within zones A1—A30 unless the applicant has demonstrated that the proposed use, when combined with all other existing and reasonably anticipated uses, will not increase the water surface elevation of the one-hundred-year flood more than one foot on the average cross-section of the reach in which the development or landfill is located.
- Nonresidential lowest floor elevation or floodproofing
New construction or substantial improvements of nonresidential structures shall have the lowest floor, including basement, elevated to or above the regulatory base flood elevation or, together with attendant utility and sanitary facilities, be designed so that below the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy.
- Residential lowest floor elevation
New construction or substantial improvements of residential structures shall have the lowest floor, including basements, elevated to or above the regulatory base flood elevation.
- Watercourse alteration capacity
In case any watercourse is allowed to be relocated or altered, the flood-carrying capacity within the altered or relocated portion of any watercourse shall be maintained.
Other
- Anchoring to prevent flotation
New construction, substantial improvements, prefabricated buildings and other developments shall be designed or anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy.
- Development permit required
A development permit shall be obtained before any construction or other development begins within any area of special flood hazard identified in Section 18.32.030.
- Flood-resistant construction materials
New development and substantial improvements shall use construction materials and utility equipment that are resistant to flood damage as specified in FEMA Technical Bulleting TB 2-93; and use construction methods and practices that will minimize flood damage consistent with economic practicability; and be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.
- Floodproofing certification
Applicants shall provide certification by a registered professional engineer or architect that floodproofing plans are adequate to be watertight with walls impermeable to the passage of water, withstand the hydrostatic and hydrodynamic forces associated with the one-hundred-year flood depths, pressures, velocities, impact and uplift forces and other factors associated with the base flood.
- Utility and sanitary facilities floodproofing1 ft above 100-year flood
Utility and sanitary facilities shall be floodproofed to one foot above the one-hundred-year flood elevation, unless a higher elevation is recommended by the floodplain administrator...
- VarianceVariancePermission to depart from a specific dimensional rule, granted on a showing of hardship. conditions for floodproofing
Variances may be issued for new construction, substantial improvement, and other proposed new development to be erected on a lot of one-half acre or less in size contiguous to and surrounded by lots with existing structures constructed below the base flood level, providing that the procedures and provisions for flood hazard reduction in this chapter have been fully considered.
- Water and sewer system flood design
Water and sanitary sewer systems shall be designed to minimize or eliminate infiltration of floodwaters and discharges into floodwaters, and on-site waste disposal systems shall be located so as to avoid impairment or contamination during flooding.
Use
- Recreational vehicle occupancy limit1 year
All recreational vehicles placed on sites within Zones A1-30 and intended for temporary occupancy... will be on the site for no longer than a maximum of one year, and be fully licensed and ready for highway use.
From the ordinance
The provisions of this section apply to land and structures in the special flood hazard areas as identified by the Federal Insurance Administration (FIA) of the Federal Emergency Management Agency (FEMA) in the flood insurance study (FIS) dated April 1978 and accompanying FIRMs and flood boundary and floodway maps (FBFMs) dated November 13, 1979, and all subsequent amendments and/or revisions are hereby adopted by reference and declared to be part of this chapter.